M3 ARK with Tonometry

  • Description
  • Information
  • Testimonials

The Marco M3 tonometry equipment offers the same space and time saving features as well as the dependability of the original M3, because it is 3 instruments in one, the only one of its kind. The M3 presents several enhanced features such as a smaller footprint, to save even more space, and a new exterior design, but most importantly, the M3 now uses SLD (Super Luminescent Diode) and a highly sensitive CCD device to provide Zonal Ring-Image Technology. This makes it possible to now accurately measure patients with cataracts, corneal opacities, IOLs, and post LASIK.  

 

  • Automatic Refraction
  • Automatic Keratometry
  • Non-Contact Tonometry
  • Space Saving
  • Time Saving
  • High-Speed Measurements
  • Accurate Data
  • EyeTracking System
  • Auto Measure
  • Adjustable Monitor
  • Motorized Chinrest
  • Softer Air Puff
  • Specifications
  • Brochures
  • Auto Refractor/Keratometer Measurable Range
  • Sphere –30.00D to +25.00D (V.D. =12mm), (0.01/0.12/0.25D increments)
  • Cylinder 0D to ±12D (0.01/0.12/0.25D increments)
  • Axis 0° to 180° (1°/5° increments)
  • Minimum Measurable Pupil Diameter 2mm
  • Chart Scenery chart (balloon target)
  • Radius Curvature 5.00 to 13.00mm (0.01mm increments)
  • Corneal Refractive Power 25.96D to 67.50D (n=1.3375), (0.01/0.12/0.25D increments)
  • Auto Track & Automatic Data Capture X-Y-Z direction, Automatic Data Capture
  • PD Measurable Range 30.00mm to 85.00mm (indication increments: 1mm)
  • Corneal Size (CS) 8.1mm–14.6mm (indication increments: 0.1mm)
  • Pupil Size (PS) 0.8mm–12.1mm (indication increments: 0.1mm)
  • Non-Contact Tonometer
  • Measurement Range 1mm Hg to 60mm Hg
  • Measurement Range Settings APC40, APC60 (APC=Automatic Puff Control) 40, 60 Standard PC p uff does not automatically adjust
  • Working Distance 11.0mm
  • Eye Fixation Inner Fixation Light
  • Auto Track & Automatic Data Capture X-Y-Z direction, Automatic Data Capture    
  • General Information
  • Monitor Multi-position tilt 5.7 inch color LCD
  • Printer Thermal line printer with automatic paper cutter
  • Power Supply AC 100-240 V±10%, 50/60Hz
  • Power Consumption 100VA
  • Dimensions & Weight 10.23”(W) x 18.93”(D) x 19.9”(H) / 50.7 lbs.
  • Standard Accessories Spare printer paper, Chinrest paper, Power cord, Dust cover, Model eye
  • Print
Richard Prince

The incorporation of the new EPIC-5100 automated refraction system along with the M3/TonoRef II into our practice has not only made the routine and post-op refractions more accurate, but has improved our refractive cataract surgery work flow - the post-op interim examinations between the two surgeries is quicker, more accurate and does not require any eye drops. Our technical staff really appreciate the enhancement to their work flow as well!

Richard Prince, MD
Southampton, PA

Richard Edlow

We successfully increased our patient volume with the simple addition of a piece of equipment from Marco. We traded out our old autorefractor with the M3 which rapidly provides precise objective refraction, keratometry, and non-contact tonometry. I added one additional patient per hour when we implemented the M3 (operated by a staff member) so it quickly paid for itself.

Richard Edlow, OD
Lutherville, MD

Michael Chow

The M3 from Marco provides us with fast and accurate refractive and keratometric measurements. The tonometry measurements are extremely accurate compared to Goldmann readings on the same patient. We decided to adopt EMR in our office; we are able to upload all the data from the M3 and the rest of our refraction directly into our EMR with a click of a button, where it becomes a permanent part of the exam record.

Michael Chow, OD, MBA
Seattle, WA