Phoenix Meibography Workstation

Phoenix Meibography Workstation

Phoenix Meibography Workstation

The Marco Phoenix Meibography Workstation is a state-of-the-art device that provides thorough dry eye assessments in addition to corneal topography measurements.

Phoenix Meibography Workstation

The Marco Phoenix Meibography Workstation is a state-of-the-art device that provides thorough dry eye assessments in addition to corneal topography measurements.

 

High-resolution imaging is combined with advanced software analysis tools to provide accurate and reliable diagnostic information that includes a comprehensive dry eye report and full topographic data. The Phoenix workstation features an easy-to-use interface, allowing clinicians to capture detailed images and analysis of the meibomian glands in a matter of seconds, providing quantitative data on gland structure, function, and distribution.

  • Meibomian gland imaging and analysis
  • Tear film analysis with non-invasive break-up times (NI-BUT)
  • Tear meniscus height analysis
  • Interference pattern imaging of lipid layer
  • Keratoconus screening with classification
  • Integrated pupillography
  • Conjunctival and limbal redness evaluation
  • Fluorescein imaging
  • Corneal OPD wavefront analysis
  • Topography/Keratometry

View Product Request Quote

Features:

  • Meibomian gland imaging and analysis
  • Tear film analysis with non-invasive break-up times (NI-BUT)
  • Tear meniscus height analysis
  • Interference pattern imaging of lipid layer
  • Keratoconus screening with classification
  • Integrated pupillography
  • Conjunctival and limbal redness evaluation
  • Fluorescein imaging
  • Corneal OPD wavefront analysis
  • Topography/Keratometry
va-1

Make more informed decisions about patient care and provide targeted treatments that address the underlying causes of dry eye disease.

  • Phoenix Reports
  • Phoenix Reports
  • Phoenix Reports
  • Phoenix Reports

Comprehensive Reports

The Phoenix Meibography Workstation provides a wide range of reports integral for accurate assessment and diagnosis.

  • Interactive dry eye reports
  • Topography reports
  • Meibomian gland imaging
  • Tear meniscus height measurement
  • Non-invasive tear film break-up

Advanced algorithms and intuitive software generate a comprehensive dry eye report as well as full topographic data.

Phoenix Meibography Workstation Specifications

Technical Details

Data Transfer USB3
Main Power External power supply 24 VCC. In: 100- 240Vac – 50/60Hz – 0.9-05A Out: 24Vdc -40W
Net cable with C14 socket
Dimensions 610 cm (h) x 206 cm (w) x 320 cm (d)
Weight Approximately 13 pounds
Dimensions (HxWxD) 515x315x255 mm
Weight 6.5 kg
Chin rest stroke 70mm
Minimum height of the chin cup from the working plan 24 cm
Base movement (x,y,z) 105x110x30 mm
Working distance 74 mm

Light Sources

Placido Placido
Fluorescein stimulation LED @470 nmm
Pupillography and meibography LED @875 nm

Topography

Placido Disk 24 W x D x H
Measured points 6144
Topographic covering (in 43D) 10 mm
Accuracy Class A according to UNI EN ISO 19980-2012
Dioptric range from 1D to 100Dm

Phoenix Meibography Workstation

Corneal Topography
Tear Meniscus Height
Fluorescein Imaging
Meibomian Glands Imaging
Keratoconus Screening