
Phoenix Meibography Workstation
Phoenix Meibography Workstation
The Marco Phoenix Meibography Workstation is a state-of-the-art device that provides thorough dry eye assessments in addition to corneal topography measurements.
Phoenix Meibography Workstation
The Marco Phoenix Meibography Workstation is a state-of-the-art device that provides thorough dry eye assessments in addition to corneal topography measurements.
High-resolution imaging is combined with advanced software analysis tools to provide accurate and reliable diagnostic information that includes a comprehensive dry eye report and full topographic data. The Phoenix workstation features an easy-to-use interface, allowing clinicians to capture detailed images and analysis of the meibomian glands in a matter of seconds, providing quantitative data on gland structure, function, and distribution.
- Meibomian gland imaging and analysis
- Tear film analysis with non-invasive break-up times (NI-BUT)
- Tear meniscus height analysis
- Interference pattern imaging of lipid layer
- Keratoconus screening with classification
- Integrated pupillography
- Conjunctival and limbal redness evaluation
- Fluorescein imaging
- Corneal OPD wavefront analysis
- Topography/Keratometry
Dry Eye Diagnostics /
Phoenix Meibography Workstation
Features:
- Meibomian gland imaging and analysis
- Tear film analysis with non-invasive break-up times (NI-BUT)
- Tear meniscus height analysis
- Interference pattern imaging of lipid layer
- Keratoconus screening with classification
- Integrated pupillography
- Conjunctival and limbal redness evaluation
- Fluorescein imaging
- Corneal OPD wavefront analysis
- Topography/Keratometry

Make more informed decisions about patient care and provide targeted treatments that address the underlying causes of dry eye disease.
Comprehensive Reports
The Phoenix Meibography Workstation provides a wide range of reports integral for accurate assessment and diagnosis.
- Interactive dry eye reports
- Topography reports
- Meibomian gland imaging
- Tear meniscus height measurement
- Non-invasive tear film break-up
Advanced algorithms and intuitive software generate a comprehensive dry eye report as well as full topographic data.
Phoenix Meibography Workstation Specifications
Technical Details
| Data Transfer | USB3 |
|---|---|
| Main Power | External power supply 24 VCC. In: 100- 240Vac – 50/60Hz – 0.9-05A Out: 24Vdc -40W |
| Net cable | with C14 socket |
| Dimensions | 610 cm (h) x 206 cm (w) x 320 cm (d) |
| Weight | Approximately 13 pounds |
| Dimensions (HxWxD) | 515x315x255 mm |
| Weight | 6.5 kg |
| Chin rest stroke | 70mm |
| Minimum height of the chin cup from the working plan | 24 cm |
| Base movement (x,y,z) | 105x110x30 mm |
| Working distance | 74 mm |
Light Sources
| Placido | Placido |
|---|---|
| Fluorescein stimulation | LED @470 nmm |
| Pupillography and meibography | LED @875 nm |
Topography
| Placido Disk | 24 W x D x H |
|---|---|
| Measured points | 6144 |
| Topographic covering (in 43D) | 10 mm |
| Accuracy | Class A according to UNI EN ISO 19980-2012 |
| Dioptric range | from 1D to 100Dm |
Phoenix Meibography Workstation








